I-SVC (TND, TNS) uchungechunge lokunemba okuphezulu okuzenzakalelayo kwamandla kagesi we-AC azinzile kwakhiwa isilawuli se-auto-voltage, i-servo motor, isifunda sokulawula okuzenzakalelayo nokunye.Lapho i-voltage yegridi ingazinzile noma umthwalo ushintsha, isekethe yokulawula okuzenzakalelayo ishayela i-servo motor ngokuya ngokushintsha kwe-voltage ephumayo, futhi ilungisa indawo yebhulashi lekhabhoni kusilawuli se-autovoltage sothintana naye ukuze kulungiswe i-voltage ephumayo enanini elilinganiselwe. , futhi i-voltage ephumayo izinzile futhi Ithembekile, ukusebenza kahle okuphezulu, ingasebenza ngokuqhubekayo isikhathi eside.Ikakhulukazi ezindaweni ezinokuguquguquka okukhulu kwamandla kagesi wegridi noma izinguquko ezinkulu zesizini kugesi wegridi, imiphumela egculisayo ingatholwa ngokusebenzisa lo mshini.Ilungele zonke izinhlobo zemithwalo enjengamathuluzi, amamitha, nempahla yasendlini ukuze isebenze ngokujwayelekile.Umkhiqizo uhambisana ne: JB/T8749.7 standard.
Ukunikezwa kwamandla okulawulwayo kunezici zokubukeka okuhle, ukulahlekelwa okuphansi, nemisebenzi yokuvikela ephelele.Ingasetshenziswa kabanzi ekukhiqizeni, ocwaningweni lwesayensi, ekunakekelweni kwezokwelapha nempilo, ama-air conditioner, amafriji nezinye izinto zikagesi zasendlini.Kungumthombo kagesi olawulwa yi-AC osebenza kahle kanye nenani.
Umswakama we-ambient: -5°C~+40°C;
Umswakama ohlobene: hhayi ngaphezu kuka-90% (emazingeni okushisa angama-25 ° C);
Ukuphakama: ≤2000m;
Indawo yokusebenza: Egunjini elingenawo amadiphozithi amakhemikhali, ukungcola, imidiya elimazayo kanye namagesi avuthayo neziqhumane, ingasebenza ngokuqhubekayo.
Izinkomba zobuchwepheshe eziyinhloko zikhonjiswe kuThebula 1
Into/Isigaba | Isigaba esisodwa | Isigaba sesithathu | |||||||
Ibanga le-voltage yokufaka | 160 ~ 250V | 280-430V | |||||||
I-voltage ephumayo | 220V ± 2.5% | 380 ± 3% | |||||||
Inani lokuvikelwa kwe-overvoltage | 246 ± 4V | 426 ± 7V | |||||||
Isivinini esilawulayo | <1s (Ku-voltage yokufaka engu-7.5V) | ||||||||
imvamisa elinganiselwe | 50Hz | ||||||||
Amandla kagesi | Ibekezelela i-50Hz sine AC 1500V endaweni ebandayo iminithi elingu-1 | ||||||||
Layisha isici samandla | 0.8 | ||||||||
Ukusebenza kahle | >90% |
Qaphela:
1. imininingwane yobuchwepheshe yomshini ngamunye ngokubhekiselwa kulezo ezikhonjiswe ezindlini, isigaba esisodwa esingu-0.5-3kVA esino-110V±3% okukhipha amandla kagesi.
2. I-voltage yokufaka ngaphezu kobubanzi obungenhla, futhi izinkomba ezikhethekile zobuchwepheshe zingenziwa ngokwezifiso ngokuhleleka okukhethekile.
Ijika lamandla okukhiphayo, bona Umfanekiso 1:
Umfanekiso (1) Ijika lamandla okukhiphayo
I-voltage yokufaka ye-Vi
Umthamo wokukhipha we-P2
Umthamo wokuphumayo ukalwe nge-P
1. 0.5kVA-1.5kVA ukunemba okuphezulu okuzenzakalelayo ngokugcwele kwe-AC1 voltage regulator kagesi umdwebo weschematic kuMfanekiso 2.
2. umdwebo wohlelo lukagesi we-SVC-5kVA noma ngaphezulu ukhonjisiwe kuMfanekiso 3.
3. Umdwebo wohlelo lukagesi lwesilawuli se-voltage esisodwa kuMfanekiso 4.
4. Isigaba sesithathu se-voltage yesilawuli sikagesi somdwebo womdwebo weskimu kuMfanekiso 5
Imodeli No. | Amandla | Ubukhulu A x B x H (cm) | |||||||
I-SVC (isigaba esisodwa) | 0.5kVA | 19 x 18 x 15 | |||||||
1 kVA | 22 x 22 x 16 | ||||||||
1.5kVA | 22 x 22 x 16 | ||||||||
2 kVA | 27 x 24 x 21 | ||||||||
3 kVA | 24 x 30 x 23 | ||||||||
5kVA | 22 x 36 x 28 | ||||||||
7kVA | 25 x 41 x 36 | ||||||||
10kVA (evundlile) | 25 x 41 x 36 | ||||||||
10kVA (iqondile) | 32 x 35 x 57 | ||||||||
15kVA | 35 x 39 x 66 | ||||||||
20kVA | 35 x 39 x 66 | ||||||||
30kVA | 50 x 50 x 96 | ||||||||
I-SVC (izigaba ezintathu) | 1.5kVA | 49 x 35 x 17 | |||||||
3 kVA | 49 x 35 x 17 | ||||||||
4.5kVA | 49 x 35 x 17 | ||||||||
6 kVA | 28 x 33 x 68 | ||||||||
9 kVA | 33 x 33 x 76 | ||||||||
15kVA | 37 x 43 x 82 | ||||||||
20kVA | 37 x 43 x 82 | ||||||||
30kVA | 41 x 46 x 95 |
I-SVC-0.5kVA~1.5kVA Xhumana ne-AC Voltage Stabilizer:
1. Amasokhethi amabili okukhiphayo (220V)
2. Amasokhethi amabili okukhiphayo (110V)
3. I-Voltmeter (i-voltage ephumayo)
4. Isibambi se-Fuse (FU)
5. Isibani senkomba esisebenzayo (okuluhlaza)
6. Ukukhanya kwenkomba ye-Undervoltage (okuphuzi)
7. Ukushintsha kwamandla
8. Isibani senkomba ye-overvoltage (bomvu)
9. Ukugawula
10. Intambo yamandla okufaka
11. Phuma amasokhethi amathathu (220V)
I-SVC-2kVA~3kVA Xhumana ne-AC Voltage Stabilizer:
1. I-Voltmeter
2. Inkinobho yesilinganiso samandla kagesi
3. Isibani senkomba ye-overvoltage (bomvu)
4. Isibani senkomba esisebenzayo (okuluhlaza)
5. Ukushintsha kwamandla
6. Ukukhanya kwenkomba ye-Undervoltage (okuphuzi)
7. Ukugawula
8. Intambo yesigaba sokufaka
9. Faka umugqa ongathathi hlangothi
10. Intambo yesigaba sokuphumayo (110V)
11. Umugqa onguziro ophumayo (110V)
12. Intambo yesigaba sokuphumayo (220V)
13. Ulayini onguziro ophumayo (220V)
Qaphela: Ngendlela yokufakwa kwezintambo, isigaba esisodwa SVC-2kVA~5kVA, kufanele ukhulule izikulufu zezintambo ezigxilile ngemuva kwepuleti elingezansi.Indawo ye-cross-sectional yezintambo ihlangabezana nezidingo zobuningi bamanje ngaphansi komthwalo.Futhi ngokugcwele, yibophe.Akuvunyelwe ngokuphelele ukukhulula izikulufu ezilungisa izintambo zangaphakathi kumugqa ongaphambili webhodi letheminali futhi usebenzise izintambo ezingahlangabezani nomthamo wangempela.
Ubukhulu bomkhiqizo buboniswa kuMfanekiso 6.
Ukunikezwa kwamandla okulawulwayo kunezici zokubukeka okuhle, ukulahlekelwa okuphansi, nemisebenzi yokuvikela ephelele.Ingasetshenziswa kabanzi ekukhiqizeni, ocwaningweni lwesayensi, ekunakekelweni kwezokwelapha nempilo, ama-air conditioner, amafriji nezinye izinto zikagesi zasendlini.Kungumthombo kagesi olawulwa yi-AC osebenza kahle kanye nenani.
Umswakama we-ambient: -5°C~+40°C;
Umswakama ohlobene: hhayi ngaphezu kuka-90% (emazingeni okushisa angama-25 ° C);
Ukuphakama: ≤2000m;
Indawo yokusebenza: Egunjini elingenawo amadiphozithi amakhemikhali, ukungcola, imidiya elimazayo kanye namagesi avuthayo neziqhumane, ingasebenza ngokuqhubekayo.
Izinkomba zobuchwepheshe eziyinhloko zikhonjiswe kuThebula 1
Into/Isigaba | Isigaba esisodwa | Isigaba sesithathu | |||||||
Ibanga le-voltage yokufaka | 160 ~ 250V | 280-430V | |||||||
I-voltage ephumayo | 220V ± 2.5% | 380 ± 3% | |||||||
Inani lokuvikelwa kwe-overvoltage | 246 ± 4V | 426 ± 7V | |||||||
Isivinini esilawulayo | <1s (Ku-voltage yokufaka engu-7.5V) | ||||||||
imvamisa elinganiselwe | 50Hz | ||||||||
Amandla kagesi | Ibekezelela i-50Hz sine AC 1500V endaweni ebandayo iminithi elingu-1 | ||||||||
Layisha isici samandla | 0.8 | ||||||||
Ukusebenza kahle | >90% |
Qaphela:
1. imininingwane yobuchwepheshe yomshini ngamunye ngokubhekiselwa kulezo ezikhonjiswe ezindlini, isigaba esisodwa esingu-0.5-3kVA esino-110V±3% okukhipha amandla kagesi.
2. I-voltage yokufaka ngaphezu kobubanzi obungenhla, futhi izinkomba ezikhethekile zobuchwepheshe zingenziwa ngokwezifiso ngokuhleleka okukhethekile.
Ijika lamandla okukhiphayo, bona Umfanekiso 1:
Umfanekiso (1) Ijika lamandla okukhiphayo
I-voltage yokufaka ye-Vi
Umthamo wokukhipha we-P2
Umthamo wokuphumayo ukalwe nge-P
1. 0.5kVA-1.5kVA ukunemba okuphezulu okuzenzakalelayo ngokugcwele kwe-AC1 voltage regulator kagesi umdwebo weschematic kuMfanekiso 2.
2. umdwebo wohlelo lukagesi we-SVC-5kVA noma ngaphezulu ukhonjisiwe kuMfanekiso 3.
3. Umdwebo wohlelo lukagesi lwesilawuli se-voltage esisodwa kuMfanekiso 4.
4. Isigaba sesithathu se-voltage yesilawuli sikagesi somdwebo womdwebo weskimu kuMfanekiso 5
Imodeli No. | Amandla | Ubukhulu A x B x H (cm) | |||||||
I-SVC (isigaba esisodwa) | 0.5kVA | 19 x 18 x 15 | |||||||
1 kVA | 22 x 22 x 16 | ||||||||
1.5kVA | 22 x 22 x 16 | ||||||||
2 kVA | 27 x 24 x 21 | ||||||||
3 kVA | 24 x 30 x 23 | ||||||||
5kVA | 22 x 36 x 28 | ||||||||
7kVA | 25 x 41 x 36 | ||||||||
10kVA (evundlile) | 25 x 41 x 36 | ||||||||
10kVA (iqondile) | 32 x 35 x 57 | ||||||||
15kVA | 35 x 39 x 66 | ||||||||
20kVA | 35 x 39 x 66 | ||||||||
30kVA | 50 x 50 x 96 | ||||||||
I-SVC (izigaba ezintathu) | 1.5kVA | 49 x 35 x 17 | |||||||
3 kVA | 49 x 35 x 17 | ||||||||
4.5kVA | 49 x 35 x 17 | ||||||||
6 kVA | 28 x 33 x 68 | ||||||||
9 kVA | 33 x 33 x 76 | ||||||||
15kVA | 37 x 43 x 82 | ||||||||
20kVA | 37 x 43 x 82 | ||||||||
30kVA | 41 x 46 x 95 |
I-SVC-0.5kVA~1.5kVA Xhumana ne-AC Voltage Stabilizer:
1. Amasokhethi amabili okukhiphayo (220V)
2. Amasokhethi amabili okukhiphayo (110V)
3. I-Voltmeter (i-voltage ephumayo)
4. Isibambi se-Fuse (FU)
5. Isibani senkomba esisebenzayo (okuluhlaza)
6. Ukukhanya kwenkomba ye-Undervoltage (okuphuzi)
7. Ukushintsha kwamandla
8. Isibani senkomba ye-overvoltage (bomvu)
9. Ukugawula
10. Intambo yamandla okufaka
11. Phuma amasokhethi amathathu (220V)
I-SVC-2kVA~3kVA Xhumana ne-AC Voltage Stabilizer:
1. I-Voltmeter
2. Inkinobho yesilinganiso samandla kagesi
3. Isibani senkomba ye-overvoltage (bomvu)
4. Isibani senkomba esisebenzayo (okuluhlaza)
5. Ukushintsha kwamandla
6. Ukukhanya kwenkomba ye-Undervoltage (okuphuzi)
7. Ukugawula
8. Intambo yesigaba sokufaka
9. Faka umugqa ongathathi hlangothi
10. Intambo yesigaba sokuphumayo (110V)
11. Umugqa onguziro ophumayo (110V)
12. Intambo yesigaba sokuphumayo (220V)
13. Ulayini onguziro ophumayo (220V)
Qaphela: Ngendlela yokufakwa kwezintambo, isigaba esisodwa SVC-2kVA~5kVA, kufanele ukhulule izikulufu zezintambo ezigxilile ngemuva kwepuleti elingezansi.Indawo ye-cross-sectional yezintambo ihlangabezana nezidingo zobuningi bamanje ngaphansi komthwalo.Futhi ngokugcwele, yibophe.Akuvunyelwe ngokuphelele ukukhulula izikulufu ezilungisa izintambo zangaphakathi kumugqa ongaphambili webhodi letheminali futhi usebenzise izintambo ezingahlangabezani nomthamo wangempela.
Ubukhulu bomkhiqizo buboniswa kuMfanekiso 6.